Foundation advice and foundation drawings

Our Geotechnical engineer would be happy to advise you on the required type of foundation whether this is a shallow foundation, a piled foundation, a retaining wall foundation, a foundation on a slope or a foundation on weak soil. Our foundations are also designed and verified for uplift forces caused by cyclone wind in the event that a unit will be built in a cyclone prone area.

For complicated issues our engineer may ask for a copy of the soil investigation report along with the SPT graphs, bore logs and/or laboratory test results.

We will supply a set of foundation drawings showing footing locations, details, rebar drawings (*) and the type and number of Simpson anchors to be installed. We offer the foundation drawings free of charge, provided a fabrication order for the wooden house has materialized. Below we show a typical set of foundation drawings for a project using a shallow footing foundation.

(*) The preparation of rebar drawings depend on the local concrete codes. In the event that the IBC and ACI codes are permitted we may prepare the rebar drawings. To this end the client neds to issue a variation order to cover our engineering costs. In the event that the IBC and ACI codes are not permitetd, whereas local codes have to be applied, the client needs to engage a local engineer.    

 

 Foundation footings Foundation pedestals  Foundation simpson anchors  Foundation column locations 
 Dimensions of pedestals Simpson anchor CB66  Simpson anchor CB44  Column strips 

 

Shallow-footing
 

 

 

Reviews from Bali Prefab World

On November 7, 2013 typhoon Haiyan, known as typhoon Yolanda in the Philippines, was the second deadliest on record that hit the archipelago killing over 4,000 peoiple which we deeply regret. The system's one-minute sustained winds reached to 315 km/h (196 mph), unofficially making Haiyan the 4th most intense tropical cyclone ever observed and made it the strongest tropical cyclone to make landfall on record. Our engineering department designs our units in cyclone areas to cyclone rating and have added a 10% additional wind force to the general cyclone design codes to cope with global warming, introducing stronger cyclones in the future. Our unit A-2 sustained typhoon Haiyan and survived. This is what the owner wrote us:
"There were minor damages and the roof remained fully in tact. Your clients should know though that this house was properly designed and built with typhoons in mind. Good job Bali Prefab World".
Review from: Ron Catto, Philippines
Project: 50 m2 unit
Date: 21-11-2013
Rating: 5 out of 5.

Read more testimonials from Bali Prefab World: click here
Dear Visitor, In order to show proof and evidence that these testimonials are genuine you may send us an e-mail with a request to provide the e-mail address of the publisher of the testimonial. We will forthwith send you the information so that you can contact the person.
Ask a question
Read our copyrights
X

Right Click

No right click allowed